Guangzhou Xieyi Automation Technology Co., Ltd., which is established in 2011, is the unique high-tech enterprise in South China that engages in the research development, production, technical consultation and service for ultra-low temperature water vapor capture pumps and other ultra-low temperature equipment.
XIEYI WVCP Cryochillers are closed loop cryogenic refrigeration systems that provide 550 watts ~ 6,000 watts of cooling. These cryochillers can be used to capture water vapor and other condensable substances by freezing them onto a cold surface such as a Meissner coil (cryocoil). WVCP cryochillers are also used to cool objects such as electrostatic chucks used in semiconductor wafer processing.
Technical Parameter
Model | WVCP6000-S-H | WVCP6000-D-H |
Maximum cooling capacity(W) | 6000 | 6000 |
The theory maximum pumping speed of tubular cold trap(L/S) | 588000 | 588000 |
The theory maximum speed of plate cold trap(L/S) | 882000 | 882000 |
Final vacuum(mbar) | 2*10-8 | 2*10-8 |
Defrost time of maximum cold trap area(min) | <5 | <5 |
Adjustable range of defrost temperature(℃) | -20~30 | -20~30 |
Pressure control mode | Digital sensor+Mechanical switch | Digital sensor+Mechanical switch |
Quick restore balance pressure function(QRBP) | Yes | Yes |
Oil blocking proof function(OBP) | Yes | Yes |
4G Remote control | Yes | Yes |
Cold media properties | Pro-enviroment | Pro-enviroment |
Maximum surface area of tubular cold trap(㎡) | 4 | 4 |
Maximum surface area of plate cold trap(㎡) | 6 | 6 |
Specification of single cold trap(㎡) | φ16mm*80m | / |
Specification of double cold trap(㎡) | / | 2*φ16mm*40m |
Gas interface | 12.7 copper welded junction(Standard) | 12.7 copper welded junction(Standard) |
ParkerCPI/VCR(Optional) | ParkerCPI/VCR(Optional) | |
Cooling water flow(L/Min at 24℃) | 48 | 48 |
Cooling water alarm temperature(℃) | 38 | 38 |
Cooling tower | Yes | Yes |
Cooling water connector(L/S) | G1” | G1” |
Maximum load power(kW) | 25.3 | 25.3 |
Compressor nominal power(HP) | 20 | 20 |
Power supply(50HZ) | 380-400V AC 3P(H) | 380-400V AC 3P(H) |
200-230V AC 3P(L) | 200-230V AC 3P(L) | |
Dimension(MM) | 935(L)*873(D)*1809(H) | 1235(L)*873(D)*1809(H) |
Weight(KG) | 655 | 655 |
Product detail pictures:
Related Product Guide:
Our improvement depends on the superior equipment, excellent talents and continuously strengthened technology forces for 2021 China New Design Cryogenic Cooling System - WVCP6000 Water Vapor Cryopump Cryogenic Refrigeration Systems – Xieyi , The product will supply to all over the world, such as: Poland, Hamburg, New York, We have top engineers in these industries and an efficient team in the research. What is more, we have our own archives mouths and markets in China at low cost. Therefore, we can meet different inquiries from different clients. Please find our website to check more information from our products.
By Erica from Lebanon - 2017.08.18 11:04
The customer service staff's answer is very meticulous, the most important is that the product quality is very good, and packaged carefully, shipped quickly!
By Eartha from Malta - 2017.08.18 11:04
Write your message here and send it to us