Product Description
Guangzhou Xieyi Automation Technology Co., Ltd., which is established in 2011, is the unique high-tech enterprise in South China that engages in the research development, production, technical consultation and service for ultra-low temperature water vapor capture pumps and other ultra-low temperature equipment.
XIEYI WVCP Cryochillers are closed loop cryogenic refrigeration systems that provide 550 watts ~ 6,000 watts of cooling. These cryochillers can be used to capture water vapor and other condensable substances by freezing them onto a cold surface such as a Meissner coil (cryocoil). WVCP cryochillers are also used to cool objects such as electrostatic chucks used in semiconductor wafer processing.
Technical Parameter
Model | WVCP6000-S-H | WVCP6000-D-H |
Maximum cooling capacity(W) | 6000 | 6000 |
The theory maximum pumping speed of tubular cold trap(L/S) | 588000 | 588000 |
The theory maximum speed of plate cold trap(L/S) | 882000 | 882000 |
Final vacuum(mbar) | 2*10-8 | 2*10-8 |
Defrost time of maximum cold trap area(min) | <5 | <5 |
Adjustable range of defrost temperature(℃) | -20~30 | -20~30 |
Pressure control mode | Digital sensor+Mechanical switch | Digital sensor+Mechanical switch |
Quick restore balance pressure function(QRBP) | Yes | Yes |
Oil blocking proof function(OBP) | Yes | Yes |
4G Remote control | Yes | Yes |
Cold media properties | Pro-enviroment | Pro-enviroment |
Maximum surface area of tubular cold trap(㎡) | 4 | 4 |
Maximum surface area of plate cold trap(㎡) | 6 | 6 |
Specification of single cold trap(㎡) | φ16mm*80m | / |
Specification of double cold trap(㎡) | / | 2*φ16mm*40m |
Gas interface | 12.7 copper welded junction(Standard) | 12.7 copper welded junction(Standard) |
ParkerCPI/VCR(Optional) | ParkerCPI/VCR(Optional) | |
Cooling water flow(L/Min at 24℃) | 48 | 48 |
Cooling water alarm temperature(℃) | 38 | 38 |
Cooling tower | Yes | Yes |
Cooling water connector(L/S) | G1” | G1” |
Maximum load power(kW) | 25.3 | 25.3 |
Compressor nominal power(HP) | 20 | 20 |
Power supply(50HZ) | 380-400V AC 3P(H) | 380-400V AC 3P(H) |
200-230V AC 3P(L) | 200-230V AC 3P(L) | |
Dimension(MM) | 935(L)*873(D)*1809(H) | 1235(L)*873(D)*1809(H) |
Weight(KG) | 655 | 655 |
Product detail pictures:
Related Product Guide:
Our items are commonly identified and trusted by customers and may fulfill continuously switching economic and social wants of Short Lead Time for Air Cooled Industrial Chiller - WVCP6000 Water Vapor Cryopump Cryogenic Refrigeration Systems – Xieyi , The product will supply to all over the world, such as: America, Netherlands, kazakhstan, We've a skilled sales team, they have mastered the best technology and manufacturing processes, have years of experience in foreign trade sales, with customers able to communicate seamlessly and accurately understand the real needs of customers, providing customers with personalized service and unique merchandise.
By Maggie from Angola - 2018.02.04 14:13
With a positive attitude of "regard the market, regard the custom, regard the science", the company works actively to do research and development. Hope we have a future business relationships and achieving mutual success.
By Agnes from Johor - 2017.10.23 10:29
Write your message here and send it to us